We use cookies to provide you with a better experience. By continuing to browse the site you are agreeing to our use of cookies in accordance with our Privacy Policy.
Home » Development of an Actuator for Ambient to Cryo Application
Development of an Actuator for Ambient to Cryo Application
December 1, 2010
During the qualification campaign of the NIRSpec (near-infrared spectrometer) instrument mechanism, the actuator could not achieve the expected lifetime that had been extended during the development phase. The initial design could not be adapted to the requested number of revolutions during that phase. Consequently the actuator needed to be modified so that the function of the mechanism would not be
endangered or, by extension, the overall function of the NIRSpec instrument. The modification included a
change of the overall actuator design—internal dimensions, tolerances, materials, lubrication and assembly
process—while keeping the interface to the mechanism, mass and function.