Operational Improvements
December 11, 2024
The Adcole 1310 is fully automatic and uses separate measuring heads for every journal and cam lobe. The gage has a 0.1 micron resolution and takes one data point each 1/10th degree or 36 data points per revolution. Adjustable followers allow quick changeover for inspecting different camshafts. It can measure 10 or more parameters that include radius, profile, taper, crown, timing angle, diameter, velocity, acceleration, runout and roundness and concentricity.